Machines for the medical industry
Automtic sleeve winder
ANR-11

The machine has 4 winding heads. Sleeve with different width and the same thickness may be operated on each of the heads. On each spindle may by winding parallel two sleeves. Each single head may be disengaged.

The machine is equipped with:

  • microprocessor control system
  • drive motor electronic control equipped with frequency changer (inverter)
  • pneumatic operating systems

Thus a fully automatic process is assured as well as single automatic operations are programmed in the most adequate way. The machine operation consists in introducing sleeve on winding spindles and taking out containers with ready-wound sleeve hanks.

Following operations are covered by automatic control:

  • fixing sleeve end at the beginning of the winding operation
  • stopping the winding operation when a programmed sleeve length is reached
  • cutting off sleeve
  • taking off hank from spindle
  • placing hank in storage container at the end of conveyor

Technical solutions applied in the machine provide in consequence for:

  • big operational capacity
  • tape of the same length on each outlet
Use of the device
Automatic sleeve winder ANR-11 is designed for winding non-flexible sleeve-bandage with a programmed length round hanks supplied for distribution.

Description:

Unit:

Quantity:

Number of outlets

pcs

4

Max diameter of the feed bobbin

mm

450

Feed package (quadratic hole)

mm

62

Winding speed (stepless regulation)

m/min

20 – 85

Width of the sleeve bandage

mm

50 – 200

Length of the sleeve in a roll

m

2 – 10

Max. diameter of the sleeve in a roll

mm

100

Exemplary productivity for the rolls 10m long from 4 outlets

pcs/h

~1000

Overall dimensions (length x width x height)

mm

3450 x 1035 x 1700

Weight of the machine

kg

450

Power installed

kW

0,85

Power supply

V

3Ph 400 N/PE

Nominal current

A

5

Control voltage

VDC

24

Supply voltage frequency

Hz

50 – 60

Pressure of the pneumatic system

MPa

0,6

Approximate air consumption

Nl/min

80

Noise level in the place of work

dB

75